Determine exhaust NFA
Start from the attic ventilation requirement that applies to the assembly.
Allocate the intended exhaust share before converting airflow to ridge length.
Use product NFA per foot
Ridge vents publish net free area ratings per linear foot.
Divide required exhaust square inches by that rating rather than by the vent's physical width.
Check usable ridge
Only ridge length that can be opened and vented according to the installation instructions should be counted.
Short hips, intersections, fire separations, or structural details can limit usable length.
Confirm intake balance
Exhaust cannot perform as intended without adequate low intake airflow.
Size soffit or other intake vents from their published NFA and keep insulation from blocking the air path.
Round to product lengths
Convert required linear feet to the stocked vent sections or rolls and round up.
Follow slot-width, end-clearance, fastening, weather, and shingle-cap instructions for the selected system.